Memory System: Difference between revisions
(→Bus Error Attribute: Add more information about attribute register) |
(Add location of all SSX regs base addresses, add / rework registers descriptions) |
||
Line 35: | Line 35: | ||
== Generalities == | == Generalities == | ||
The bus fabric of Kermit is made of several SonicsSX® interconnects on which peripherals are connected. | |||
All communication is done using the OCP protocol; however, adapters (e.g., AXI2OCP for Cortex-A9) may be present at Agent level. | |||
There are three revisions of the memory system layout: | There are three revisions of the memory system layout: | ||
* Original layout for Kermit1.0 ES1 - uses the SMX interconnect ( | * Original layout for Kermit1.0 ES1 - uses the SMX interconnect (as found in BeagleBoard SoC) instead of SSX | ||
* Second revision for Kermit1.0 ES2 - very close to the final revision, uses the SSX interconnect | * Second revision for Kermit1.0 ES2 - very close to the final revision, uses the SSX interconnect | ||
* Third and final revision for Kermit1.0 ES3 and later | * Third and final revision for Kermit1.0 ES3 and later | ||
Line 52: | Line 56: | ||
This is sometimes used for access checks, or to identify transaction initiator when a bus error occurs. | This is sometimes used for access checks, or to identify transaction initiator when a bus error occurs. | ||
== | == Interconnect registers == | ||
There are register blocks associated to each interconnect in the system. These blocks are always 1KiB (0x400 bytes), and the registers inside them are always 64-bit. | |||
=== Location === | |||
{| class="wikitable" style="text-align: center" | |||
|- | |||
! Address !! Name !! UIID | |||
|- | |||
| 0xEC000000 || Main Xbar || 0 | |||
|- | |||
| 0xEC100000 || Center Xbar || 1 | |||
|- | |||
| 0xEC200000 || Video Xbar || 2 | |||
|- | |||
| 0xEC300000 || IFTU Xbar || 3 | |||
|- | |||
| 0xEC400000 || VIP Xbar || 4 | |||
|- | |||
| 0xEC500000 || Debug Bus || 5 | |||
|- | |||
| 0xEC600000 || DMAC Xbar || 6 | |||
|- | |||
| 0xED000000 || IO Slave Bus || 8 | |||
|- | |||
| 0xED100000 || IO Master Bus || 9 | |||
|- | |||
| 0xED200000 || Pervasive Bus || 10 | |||
|- | |||
| 0xED300000 || Misc IO Bus || 11 | |||
|- | |||
| 0xED400000 || North IO Master Bus || 12 | |||
|- | |||
| 0xED500000 || Audio Bus || 13 | |||
|- | |||
| 0xED600000 || North IO Slave Bus || 14 | |||
|- | |||
| 0xED700000 || SRC Bus || 15 | |||
|- | |||
| 0xED800000 || GPU Register Bus || 16 | |||
|- | |||
| 0xED900000 || IFTU Register Bus || 17 | |||
|- | |||
| 0xEE000000 || Camera Slave Bus || 24 | |||
|- | |||
| 0xEE100000 || Camera Master Bus || 25 | |||
|- | |||
| 0xEE200000 || USB Slave Bus || 26 | |||
|- | |||
| 0xEE300000 || USB Master Bus || 27 | |||
|- | |||
| 0xEE400000 || SubLCD Slave Bus || 28 | |||
|- | |||
| 0xEE500000 || SubLCD Master Bus || 29 | |||
|- | |||
| 0xEE600000 || Camera Register Bus || 30 | |||
|- | |||
| 0xE00C0000 || Cry/SBL Bus || 48 | |||
|- | |||
|} | |||
The <code>UIID</code> column indicates the '''U'''nique '''I'''nterconnect '''ID'''. | |||
Bit <code>N</code> of BEBT register indicates an error is pending on interconnect with UUID <code>N</code>. | |||
Each interconnect register group is divided as follows: | |||
{| class="wikitable" style="text-align: center" | |||
|- | |||
! Address mask !! Sub-block !! Description | |||
|- | |||
| <code>0xEoo00000</code> || ? || ?Sideband Interconnect? | |||
|- | |||
| <code>0xEoo1xx00</code> || ? || IA-related (Only present if IA exists at <code>0xEoo4xx00</code>) | |||
|- | |||
| <code>0xEoo30000</code> || ? || ? | |||
|- | |||
| <code>0xEoo30400</code> || ? || ? | |||
|- | |||
| <code>0xEoo3C000</code> || ? || ? | |||
|- | |||
| <code>0xEoo4xx00</code> || IA || Initiator Agent - one block for each initiator on the interconnect. Cross-interconnect IAs usually start at offset 0x8000. | |||
|- | |||
| <code>0xEoo5xx00</code> || TA || Target Agent - one block for each target on the interconnect. Cross-interconnect TAs usually start at offset 0x8000. | |||
|- | |||
| <code>0xEoo6xx00</code> || PM || Protection Mechanism - used to filter access to specific targets. If present, register block at <code>0xEoo6xx00</code> protects TA <code>0xEoo5xx00</code>. | |||
|- | |||
| <code>0xEoo6C000</code> || Interconnect PM || Protection Mechanism ?for the interconnect's RT? | |||
|- | |||
| <code>0xEoo70000</code> || RT || Register Target - used to interact with the interconnect itself. | |||
|} | |||
Note: <code>Cry/SBL Bus</code> does not follow this scheme. | |||
=== Agent registers === | === Agent registers === | ||
IA and TA register blocks share a similar layout. | |||
(List of physical address for all these interfaces can be found on [[Physical Memory]] page - names start with <code>SSX_</code> - will be migrated here at some point) | (List of physical address for all these interfaces can be found on [[Physical Memory]] page - names start with <code>SSX_</code> - will be migrated here at some point) | ||
Line 94: | Line 185: | ||
|} | |} | ||
=== Register Target === | |||
Hosts configuration and status registers of the interconnect itself. | |||
{| class="wikitable | {| class="wikitable" | ||
|+ RT registers | |+ RT registers description | ||
|- | |- | ||
! | ! Name !! Offset !! Usage/Notes | ||
|- | |- | ||
| | | <code>COMPONENT</code> || 0x0 || See Agent registers | ||
|- | |- | ||
| | | <code>NETWORK</code> || 0x10 || Bits 63:48 (63:32?) hold the Unique Interconnect ID | ||
|- | |- | ||
| | | <code>INITID_READBACK</code> || 0x70 || Bits <7:0> contain the Initiator ID of the reader | ||
|- | |- | ||
| <code>NETWORK_CONTROL</code> || 0x78 || Bits <10:8> contain TIMEOUT_BASE | |||
|} | |} | ||
Note: the initiator ID is an interconnect-level concept, and unrelated to the Bus Master ID. ?Every IA has its own IID? | |||
=== Sideband Interconnect === | |||
Each interconnect hosts a register block called '''S'''ideband '''I'''nterconnect, used for error reporting. | |||
{| class="wikitable" | {| class="wikitable" | ||
|+ | |+ SI registers description | ||
|- | |- | ||
! Name !! Offset !! Usage/Notes | ! Name !! Offset !! Usage/Notes | ||
|- | |- | ||
| | | <code>SI_FLAG_STATUS_0</code> || 0x110 || Sideband Interconnect error status 0 | ||
|- | |- | ||
| | | <code>SI_FLAG_STATUS_1</code> || 0x130 || Sideband Interconnect error status 1 | ||
|- | |- | ||
| | | <code>SI_FLAG_STATUS_2</code> || 0x150 || Sideband Interconnect error status 2 | ||
|- | |- | ||
| | | <code>SI_FLAG_STATUS_3</code> || 0x170 || Sideband Interconnect error status 3 | ||
|- | |- | ||
| <code>SI_FLAG_STATUS_4</code> || 0x190 || Sideband Interconnect error status 4 | |||
|} | |} | ||
+ many registers not documented in OMAP35x TRM | |||
=== Protection Mechanism === | |||
=== | |||
Each Target Agent may be equipped with a Firewall (also called '''P'''rotection '''M'''echanism), which can be used to restrict or filter access to it based on various criteria. | Each Target Agent may be equipped with a Firewall (also called '''P'''rotection '''M'''echanism), which can be used to restrict or filter access to it based on various criteria. | ||
Line 234: | Line 281: | ||
| <code>0x003F_0000</code> || master || Bus master | | <code>0x003F_0000</code> || master || Bus master | ||
|- | |- | ||
| <code>0x0000_0700</code> || cmd || | | <code>0x0000_0700</code> || cmd || MCmd signal | ||
|- | |- | ||
| <code>0x0000_0008</code> || Burst Access Error || | | <code>0x0000_0008</code> || Burst Access Error || | ||
Line 242: | Line 289: | ||
| <code>0x0000_0001</code> || Address Hole Error || If set, the error occurred because the address was invalid. | | <code>0x0000_0001</code> || Address Hole Error || If set, the error occurred because the address was invalid. | ||
|} | |} | ||
Sometimes, this register is not present but separated in multiple (e.g., in REGBUS). | |||
Note that for some devices (Spad32K, Spad128K, Compati SRAM), the only valid attribute is <code>0x1</code>, indicating an invalid address. | Note that for some devices (Spad32K, Spad128K, Compati SRAM), the only valid attribute is <code>0x1</code>, indicating an invalid address. | ||
Line 247: | Line 296: | ||
To decode the meaning of <code>master</code> and <code>cmd</code>, shift them by 16 and 8 respectively to obtain a value between 0-63/0-7 and use the following tables: | To decode the meaning of <code>master</code> and <code>cmd</code>, shift them by 16 and 8 respectively to obtain a value between 0-63/0-7 and use the following tables: | ||
{| class="wikitable mw-collapsible mw-collapsed" | {| class="wikitable mw-collapsible mw-collapsed" | ||
|+ <code> | |+ <code>MCmd</code> table | ||
|- | |- | ||
! Value !! Command | ! Value !! Command |
Latest revision as of 22:06, 23 October 2024
This page documents Kermit memory system internals.
The OMAP35x Technical Reference Manual provides information about the SonicsMX® interconnect used in Kermit ES1. Datasheets for some Microchip PIC32 microcontrollers (e.g. PIC32MZ family) provide information about the SonicsSX® interconnect used in Kermit ES2+.
Glossary
- SMX
Abbreviation of SonicsMX®.
- SSX
Abbreviation of SonicsSX®.
- Module
Any device connected to the memory system, such as ARM cores, DMA controllers, LPDDR2... Modules can be initiators, targets or both.
- Initiator
A module that can initiate read and write requests to the interconnect (e.g. ARM cores, DMA, ...).
- Target
A module that can only respond to requests from the interconnect. Targets may also be able to generate out-of-band signals such as interrupts.
- Agent
The connection between a module's port and the interconnect. If a module has multiple ports (e.g. an Initiator and Target module), each port is connected to the interconnect by a different agent (e.g. one IA and one TA).
- TA
Short for Target Agent. The agent connecting an Initiator module to the interconnect.
- IA
Short for Initiator Agent. The agent connecting a Target module to the interconnect.
- OCP
Open-core Protocol, a standard point-to-point protocol allowing communication between a master and a slave port.
- OCP Master Port
A port that can generate OCP commands. Initiators always include at least one master port.
- OCP Slave Port
A port that can respond to OCP commands. Targets always include one slave port.
- Interconnect
Logic device enabling connection between initiator and target modules connected to it.
- Out-of-band error
OCP signal associated to a device error-reporting scheme. This is opposed to an in-band error, which is associated to the protocol's error-reporting scheme. Out-of-band errors are also known as sideband errors.
Generalities
The bus fabric of Kermit is made of several SonicsSX® interconnects on which peripherals are connected.
All communication is done using the OCP protocol; however, adapters (e.g., AXI2OCP for Cortex-A9) may be present at Agent level.
There are three revisions of the memory system layout:
- Original layout for Kermit1.0 ES1 - uses the SMX interconnect (as found in BeagleBoard SoC) instead of SSX
- Second revision for Kermit1.0 ES2 - very close to the final revision, uses the SSX interconnect
- Third and final revision for Kermit1.0 ES3 and later
In the following sections, you may see mentions of register names such as BEBT
and SBEBT
. Unless otherwise specified, a register prefixed with S
is merely the ARM Secure variant of the register e.g. SBEBT
is BEBT
for ARM Secure. Everything that applies to a register should apply to its Secure variant, except that the register is updated by Secure bus transactions, instead of Non-Secure bus transactions.
Signals
MReqInfo
MReqInfo
is 16 bits wide in Kermit.
Bits <6:0> contain the Bus Master ID
of initiator.
This is sometimes used for access checks, or to identify transaction initiator when a bus error occurs.
Interconnect registers
There are register blocks associated to each interconnect in the system. These blocks are always 1KiB (0x400 bytes), and the registers inside them are always 64-bit.
Location
Address | Name | UIID |
---|---|---|
0xEC000000 | Main Xbar | 0 |
0xEC100000 | Center Xbar | 1 |
0xEC200000 | Video Xbar | 2 |
0xEC300000 | IFTU Xbar | 3 |
0xEC400000 | VIP Xbar | 4 |
0xEC500000 | Debug Bus | 5 |
0xEC600000 | DMAC Xbar | 6 |
0xED000000 | IO Slave Bus | 8 |
0xED100000 | IO Master Bus | 9 |
0xED200000 | Pervasive Bus | 10 |
0xED300000 | Misc IO Bus | 11 |
0xED400000 | North IO Master Bus | 12 |
0xED500000 | Audio Bus | 13 |
0xED600000 | North IO Slave Bus | 14 |
0xED700000 | SRC Bus | 15 |
0xED800000 | GPU Register Bus | 16 |
0xED900000 | IFTU Register Bus | 17 |
0xEE000000 | Camera Slave Bus | 24 |
0xEE100000 | Camera Master Bus | 25 |
0xEE200000 | USB Slave Bus | 26 |
0xEE300000 | USB Master Bus | 27 |
0xEE400000 | SubLCD Slave Bus | 28 |
0xEE500000 | SubLCD Master Bus | 29 |
0xEE600000 | Camera Register Bus | 30 |
0xE00C0000 | Cry/SBL Bus | 48 |
The UIID
column indicates the Unique Interconnect ID.
Bit N
of BEBT register indicates an error is pending on interconnect with UUID N
.
Each interconnect register group is divided as follows:
Address mask | Sub-block | Description |
---|---|---|
0xEoo00000 |
? | ?Sideband Interconnect? |
0xEoo1xx00 |
? | IA-related (Only present if IA exists at 0xEoo4xx00 )
|
0xEoo30000 |
? | ? |
0xEoo30400 |
? | ? |
0xEoo3C000 |
? | ? |
0xEoo4xx00 |
IA | Initiator Agent - one block for each initiator on the interconnect. Cross-interconnect IAs usually start at offset 0x8000. |
0xEoo5xx00 |
TA | Target Agent - one block for each target on the interconnect. Cross-interconnect TAs usually start at offset 0x8000. |
0xEoo6xx00 |
PM | Protection Mechanism - used to filter access to specific targets. If present, register block at 0xEoo6xx00 protects TA 0xEoo5xx00 .
|
0xEoo6C000 |
Interconnect PM | Protection Mechanism ?for the interconnect's RT? |
0xEoo70000 |
RT | Register Target - used to interact with the interconnect itself. |
Note: Cry/SBL Bus
does not follow this scheme.
Agent registers
IA and TA register blocks share a similar layout.
(List of physical address for all these interfaces can be found on Physical Memory page - names start with SSX_
- will be migrated here at some point)
Name | Offset | Usage/Notes |
---|---|---|
COMPONENT |
0x0 | Bits [31:16] contain component code (CODE )
Bits [15:0] contain component revision ( ?what is component referring to? SSX? |
CORE |
0x18 | Bits [47:32] contain vendor code (VENDOR_CODE )
Bits [31:16] contain core code ( Bits [15:0] contain revision code ( |
AGENT_CONTROL |
0x20 | ? |
AGENT_STATUS |
0x28 | Bit 0x0100_0000 indicates an error |
AGENT_ERROR_LOG |
0x58 | |
AGENT_ERROR_LOG_ADDR |
0x60 | |
? | 0x100 | Seen values: 1 |
Register Target
Hosts configuration and status registers of the interconnect itself.
Name | Offset | Usage/Notes |
---|---|---|
COMPONENT |
0x0 | See Agent registers |
NETWORK |
0x10 | Bits 63:48 (63:32?) hold the Unique Interconnect ID |
INITID_READBACK |
0x70 | Bits <7:0> contain the Initiator ID of the reader |
NETWORK_CONTROL |
0x78 | Bits <10:8> contain TIMEOUT_BASE |
Note: the initiator ID is an interconnect-level concept, and unrelated to the Bus Master ID. ?Every IA has its own IID?
Sideband Interconnect
Each interconnect hosts a register block called Sideband Interconnect, used for error reporting.
Name | Offset | Usage/Notes |
---|---|---|
SI_FLAG_STATUS_0 |
0x110 | Sideband Interconnect error status 0 |
SI_FLAG_STATUS_1 |
0x130 | Sideband Interconnect error status 1 |
SI_FLAG_STATUS_2 |
0x150 | Sideband Interconnect error status 2 |
SI_FLAG_STATUS_3 |
0x170 | Sideband Interconnect error status 3 |
SI_FLAG_STATUS_4 |
0x190 | Sideband Interconnect error status 4 |
+ many registers not documented in OMAP35x TRM
Protection Mechanism
Each Target Agent may be equipped with a Firewall (also called Protection Mechanism), which can be used to restrict or filter access to it based on various criteria.
Base address | Protected TA |
---|---|
0xEC060000? | Spad_32KiB ?
|
0xEC060400 | LPDDR0 (Main LPDDR2 + Controller I/F)
|
0xEC160000? | Compati_2MiB ?
|
0xEC160400? | DevNull ?
|
0xEC260000? | Spad_128KiB ?
|
0xEC560000? | SDIO0 ?
|
0xEC560400? | SDIO1 ?
|
0xEC560800? | LPDDR1 ? (TOOL LPDDR2 + Controller I/F)
|
Bus Errors
When a bus error occurs, an interrupt is delivered to ARM Secure (Interrupt ID 0x21=33) or Non-Secure (Interrupt ID 0x20=32). The OS considers all bus errors to be fatal. The interrupt handlers installed for these IDs perform a register dump then stop the system.
It appears that device-initiated bus errors (e.g. DMAC) are always routed to Non-Secure interrupt. There may be other rules to consider (e.g. some register to set whether a device is Secure/Non-Secure).
It is unknown whether or not CMeP can receive bus error interrupts or how CMeP fits in the memory system.
There are two kind of bus errors: Internal Bus error and Target Device error. An Internal Bus error occurs when the memory system fails to deliver a request to a target device - for example, trying to access non-existent memory. A Target Device error occurs when a device successfully receives a request but is unable to handle it - for example, accessing the non-existent part of a device's memory.
Bus Error Attribute
The bus error attribute is a 32-bit value that can be recovered in a per-device MMIO register along with the bus error address.
The attribute holds multiple informations: which agent was the bus master when the error occurred, what bus command was ongoing, and, when available, the reason of the bus error.
Bitmask | Name | Notes |
---|---|---|
0xFF80_0000 |
MReqInfo<15:7> |
Bits <15:7> of MReqInfo signal |
0x003F_0000 |
master | Bus master |
0x0000_0700 |
cmd | MCmd signal |
0x0000_0008 |
Burst Access Error | |
0x0000_0004 |
Register Permission Error | |
0x0000_0001 |
Address Hole Error | If set, the error occurred because the address was invalid. |
Sometimes, this register is not present but separated in multiple (e.g., in REGBUS).
Note that for some devices (Spad32K, Spad128K, Compati SRAM), the only valid attribute is 0x1
, indicating an invalid address.
To decode the meaning of master
and cmd
, shift them by 16 and 8 respectively to obtain a value between 0-63/0-7 and use the following tables:
Value | Command |
---|---|
0 | Idle |
1 | Write |
2 | Read |
3 | ReadEx |
4 | ReadLinked |
5 | WriteNonPost |
6 | WriteConditional |
7 | Broadcast |
Value | Command |
---|---|
0 | Reserved |
1 | ARM Core0 |
2 | ARM Core1 |
3 | ARM Core2 |
4 | ARM Core3 |
5 | ARM L2 |
6 | Reserved |
7 | Reserved |
8 | Reserved |
9 | Reserved |
10 | Reserved |
11 | Reserved |
12 | Reserved |
13 | Reserved |
14 | Reserved |
15 | Reserved |
16 | DMAC0 |
17 | DMAC1 |
18 | DMAC2 |
19 | DMAC3 |
20 | DMAC4 |
21 | DMAC5 |
22 | Reserved (Bigmac?) |
23 | GPU |
24 | Venezia |
25 | VIP vdpd |
26 | VIP vdpm |
27 | VIP bap |
28 | Reserved |
29 | IFTU0a |
30 | IFTU0b |
31 | IFTU1a |
32 | IFTU1b |
33 | IFTU2 |
34 | Reserved (Compati port0 in ES1 SceKernelBusError)
|
35 | Reserved (Compati port0 in ES1 SceKernelBusError)
|
36 | USB1 Host EHCI |
37 | USB1 Host OCHI |
38 | Reserved (CMeP?) |
39 | Sensor in 0 |
40 | Sensor in 1 |
41 | Reserved (Sensor in 2 in ES1 SceKernelBusError)
|
42 | LCD DMAC |
43 | Performance Monitor |
44 | USB2 Device DMAC |
45 | Sub LCD |
46 | DMAC6 |
47 | USB0 Host EHCI |
48 | USB0 Host OHCI |
49 | USB2 Host EHCI |
50 | USB2 Host OHCI |
51 | USB0 Device DMAC |
52 | Reserved (USB1 Device DMAC1 in ES1/ES2)
|
53 | Reserved (USB1 Device DMAC2 in ES1/ES2)
|
54 | Reserved (USB1 Device DMAC3 in ES1/ES2)
|
55 | USB1 Device DMAC |
56 | Reserved (USB2 Device DMAC1 in ES1/ES2)
|
57 | Reserved (USB2 Device DMAC2 in ES1/ES2)
|
58 | Reserved (USB2 Device DMAC3 in ES1/ES2)
|
59 | SD/HSMMC0 |
60 | SD/HSMMC1 |
61 | SD/HSMMC2 |
62 | SD/HSMMC3 |
63 | Memory Stick |
Clear TA error
In old System Software versions (e.g. 0.920 - pre-ES3, so this may no longer be valid), there exists inside the bus error module a function named BusErrorClearTA
which works the following way.
First, choose a bus/XBar that will serve as start point (MainXBar for ES2).
Second, recursively build a list of all TAs connected to this start point. Repeat the process for all TAs that are busses or XBars.
Third, walk the obtained tree. Check the STATUS
of all TAs. If an error is present, repeat the procedure recursively (if bus/XBar) then clear the error.
To detect an error, check if bit 0x01000_0000ull
is present in STATUS
To clear the error, simply write 0x01000_0000ull
to STATUS
.
NOTE: old System Software versions do not have informations about IAs, but only TAs. This could explain the routine's name, but also means this procedure may also work/be needed on IA side.
Miscellaneous
The memory system is able to distinguish if a transaction is originating from ARM Secure state or Non-Secure state because ARM Cortex-A9 processors with Security Extensions have a bit indicating whether the access is Secure or Non-Secure added to all memory system transactions.
Attempting to perform a DMAC memcpy() from Secure to Non-Secure LPDDR0 region results in a NS bus error. The current hypothesis is that all devices on the Kermit bus diagram that have an IA are treated as ARM NS.