Ernie Firmware

From Vita Development Wiki
Revision as of 21:14, 6 January 2024 by CelesteBlue (talk | contribs)
Jump to navigation Jump to search

References

Manuals

Tools

Unofficial documentation

Architecture

Read the reference manual for full information. Below are the most important facts.

Memory Space

The memory is laid out into 0x800 sized blocks. The bottom X blocks are flash memory that can be programmed. Some blocks are not programmable on Ernie. Most keys reside on the non-programmable blocks.

Registers and Devices

Registers are 8-bits and adjacent registers can be addressed as 16-bits (example: register AX can be addressed as A (top 8 bits) and X (bottom 8 bits)).

Additional registers are located near the top of the memory map. They are addressed like any other memory. Ernie uses 0xFFED4-0xFFEDF as extra scratch registers.

Device registers (documented in the reference manual) are located at 0xFFF00-0xFFFFF (SFR) and 0xF0000-0xF07FF (SFR2).

The UART serial controller used by Ernie is not documented in the reference manual but the register definitions are the same as the serial controllers that are documented. There appears to be a few other registers and interrupt vectors that differ from the documentation.

Memory access is done through segmented addressing on a 20-bit address space. CS contains the top 4 bits for code access. ES contains the top 4 bits for data access.

Calling Convention

Functions with one argument: AX

Functions with one pointer argument: AX = pointer, C = segment

Functions with multiple arguments: first argument same as above, then rest are in stack using PUSH instruction. Stack pointer moves downwards.

Often, at the start of a function, the AX and BC registers are PUSH onto the stack before the frame pointer is allocated. Then the arguments are referenced by addressing the bottom of the frame pointer.

Firmware Basics

Startup

Reset vector sets up environment and calls into the Worker Loop.

Worker Loop

The Worker Loop is a FSM with 10 states (0-9). In each state, the Main function is called with the current state and the target state depending on flags that are set.

The starting state is either 0 or 7 depending on a global value derived earlier.

Flags are global variables in memory set by various sources: asynchronous interrupts, synchronous work in the current state, command handlers, etc. Not all states will handle all flags. Some flags can be handled in all states and some flags can be handled in only some states. Each flag is cleared after it is read. When multiple flags are set, the Main function will be called multiple times synchronously in a set order (certain flags have higher priority).

In states 3 and 4, after the Main Function is called (potentially multiple times depending on the flags set), the Command Handler is called.

Main Function

The Main Function is the starting point for most of Syscon's tasks. It looks at the current state (a global variable) and the target state (its only argument) to determine what to do. If the task is successful, the target state will be written to the current state variable and the function call returns to the Worker Loop.

Command Handler

Two bytes are read from SDR00. This is the command header. If the header & 0x80 == 0, then there is no data payload in the command and the command handler is invoked. One more byte is read. If there is no payload, this is the checksum. If there is a payload, the rest of the packet is read and handled in a different command table. Finally, the checksum is checked.

Asynchronous Handler

A timer (TMR00) is set up at the start of the Worker Loop to count in 0x7D00 cycle intervals. Oddly, the timer interrupt is not configured but INTCSI01 is configured. Possibly the reference manual is not correct with reference to Ernie because the interrupt handler for INTCSI01 does not appear to reference the serial interface at all. We will assume this interrupt is the timer's interrupt.

A table of software handlers are initialized to 0 at the start of the Worker Loop. Functions can register handlers in this table. Functions can also flag a handler to run at the next timer interrupt. During each timer interrupt, (with interrupt disabled) the firmware will iterate through the handlers and run any function that is flagged (and unflag it).

Jig Handler

When Syscon UART RPC is initialized, commands can be sent through a UART interface by an external agent. A UART RX interrupt will flag asynchronous handler 0xB. This handler is registered at the start of the Worker Loop to set flag 0x32 and return. In the Worker Loop, flag 0x32 can be handled by states 1, 3, 8, 9. In any of these states, the Jig Handler is called.

Jig Initialization

  1. At startup, the timer for the #Asynchronous_Handler is set up. When the interrupt is triggered at least 8 times, every time it is triggered, flag 0x79 is set.
  2. In states 0, 1, 3, 8, or 9, flag 0x79 is handled.
  3. The ADC is called on channel ANI6 (port P26). The voltage is passed to a lookup table that converts different voltage ranges to different ids. For example 1.562V - 1.622V corresponds to id 0.
  4. Repeat 1-3 and if the id value did not change, then we set a global variable to that value and set flag 0x7A.
  5. In states 0, 1, 3, 8, or 9, flag 0x7A is handled.
  6. If the id from #3 is 4 (P26 is held at 1.017V - 1.140V for at least 32000 clock cycles), then UART serial controller is configured. If bit 3 is set in KBL_Param#Hardware_Info then a hello packet is printed to UART: 0x55 0x55 0x55 ("UUU").

MultiConnector Voltage Table

The conversion is done using the equation on 11.4.2 of the Syscon manual with Vref=1.8V.

ID ADC Value Min Voltage
0 59072 1.622
1 56896 1.562
255 52608 1.444
2 50240 1.379
3 46656 1.281
255 41536 1.140
4 37056 1.017
255 34752 0.954
5 31488 0.864
255 1408 0.038
6 320 0.008
7 0 0