== OLED Vita UART0 location ==
 
== OLED Vita UART0 location ==
[[File:vita-1000-uart.png]]
+
[[File:vita-1000-uart.png|600px]]
    
Two ways of using UART0. First is to solder directly to the testpads near the PMIC (yellow and cyan points). The second way is through the multi-connector or the testpads above it (blue and red points). To use the multi-connector points though, you need either to tell the syscon to select the Kermit UART (procedure currently unknown) or manually flip the switch (green point to 1.8V).
 
Two ways of using UART0. First is to solder directly to the testpads near the PMIC (yellow and cyan points). The second way is through the multi-connector or the testpads above it (blue and red points). To use the multi-connector points though, you need either to tell the syscon to select the Kermit UART (procedure currently unknown) or manually flip the switch (green point to 1.8V).